Discharge side check valve for centrifugal slurry pumps
We were told today that we should use check valves on the discharge side of our slurry pumps to prevent possible (major) damage. We have relatively large (6,8 and 10 inch discharge diameter) pumps, discharging to 10, 12 and 16 inch diameter 30 feet high discharge manifolds. The calcium sulphate and calcium carbonate slurries we use are higly abrasive, corrosive, and tend to stick everywhere, so I assume that?s the reason why check valves weren?t installed in the first place (we do not even have discharge side valves in some of the pumps, but that can be solved easily). Are we really risking major damage to the pump in case of, for example, the impeller back-turning after a power failure because of the 30 feet discharge side water column, and somebody turning the pump back on while it is still backturning? These guy who recommended the check valve supplies the mechanical seals for some of our pumps, and he says that even the seal could be damaged by the water hammer (?) effect. Any comments will be very welcome.
In my opinion check valves in slurry service are almost a waste of time. Can your budget accommodate actuated discharge on/off valves and logic to close the valves when the pump stops?
There are a few possible reasons to need a check valve. Many ANSI pumps have impellers that are threaded on. The common argument is that the impeller will unscrew, drive itself into the case and damage the case and impeller if allowed to spin backwards from reverse flow. This is not very likely. The torque impossed on the impeller to spin it backwards would tend to tighten the impeller, not loosen it. For API pumps, the impeller would be key driven and should not unscrew. Most pumps would not necessarily suffer any mechanical seal or bearing problems from running in reverse. Oil rings work in reverse. API plan 11 or 13 seal flush might not flow at normal rates with reverse flow, but this would tend to be a long term risk, not an immediate one. The primary reason we install check valves in the discharge of our pumps is not to protect the pump, but to protect the process. If a pump trips, the second pump will often be set up to autostart. If there were no check valves, the back flow through the tripped pump would divert all available flow from the process and shut the unit down. If the pump pumps fluid from a low pressure tank to a high pressure vessel we need to protect against back flow that could over pressure the supply tank. If you don't have a process that would justify a check valve, it is probably just something else to fail. We don't use check valves in liquid sulfur applications for this reason. No check valve would be reliable and it is not needed to protect the pump or process.
Like JJPelin states, I really wouldn?t like to add another possible
failure element to the system (either check valves or automatically
actuated discharge on/off valves) without proper justification. My main
concern right now is catastrophic pump failure because of a backturning
impeller. We don?t have pumps operating in parallel, no concerns about
that, and if the pump stops because of power failure or something like
that, we simply shutdown the process, we can live with that while we
start up the system again. We have toyed with the idea of automated
discharge valves, but if a valve fails and accidentaly closes during
operation and the operations guys don?t react swiftly, THEN we risk
major damage to the process equipment because of increased
temperature. Up to now, we?ve been working ok
for 3-4 years, and have had a lot of shutdowns, power failures, etc.
with the corresponding backturning pumps after a shutdown, and no
problems whatsoever. However, when I heard this guy yesterday talking
about possible catastrophic failures because of the lack of discharge
check valves, it made me think if we should do something about it. I
can understand the stresses involved if you turn on a pump while it is
backturning after a stop, but that could be easily remedied by a timer
within the control logic, as stated by artisi.
What is not very
clear to me is how could a significant water hammer effect happen in my
system if a pump shuts down and backturns for a few moments until the
discharge column is depleted. Our system is pretty straight forward,
tank and pump are both at floor level, and have a simple 30 foot high
discharge manifold which discharges via control valves to a scrubber at
atmospheric pressure levels, no other high pressure generators
involved. I read the papers suggested by stanier (thanks by the way
stainer, very good references), but I still can?t visualize a
significant water hammer in my specific case. Any references that talk
about water hammer effects in simple pump application with a not-to-tall discharge manifold such as ours?