J61Y-250 High Pressure Welded Needle Valve Flow Parameters and Operation Manual

2026-11-18

Its conical needle tip seats into a matched orifice, delivering fine flow control that ball or gate valves cannot match in small bore service.The main needle valve product names of China needle valve Network include:ANSI J11W/H Internal And External Thread Needle Valve,ANSI J11W/H Internal Thread Needle Valve,ANSI JG-1F/JG-2F Multi-entrance Metering Valve,CJ123 Multi-functional Pressure Gage Needle Valve,EN5-4 SS-M2F8 Internal Thread Three-valve Manifold,EN5-1 SS-M2F8 Internal Thread Two-valve Manifold,EN5-2 EF-2 Two-valve Manifold,EN5-3 WF1/2 Five-valve Manifold.

Flow and Emission Parameters

The valve‘s flow capacity is expressed by the Cv coefficient. Published data for the J61Y-250 series gives Cv values of approximately 0.7 for 1/4 inch connections, 0.8 for 3/8 inch, and 1.2 for 1/2 inch configurations. These low values reflect the needle valve‘s design intent: precise throttling rather than high volume throughput. For emission related calculations, the seat leakage class and the discharge coefficient through the needle orifice should be taken from the manufacturer’s test certificate, as the effective flow area varies with stem position.

Operation Manual

Installation preparation. Before installation, flush and clean the pipeline to remove residual debris. Install a filter upstream where practical to prevent particles from lodging against the needle and seat. Confirm that the medium flow direction matches the arrow on the valve body, and complete the welded connection in accordance with the applicable welding procedure.

Opening and closing. The valve is a rising-stem, handwheel-operated design. Rotate the handwheel clockwise to drive the needle downward toward the seat and close the flow path. Rotate counterclockwise to lift the needle away from the seat and open the valve. Because the needle travels a long stroke relative to the seat orifice, operate the handwheel slowly and steadily. Rapid movement can damage the sealing surfaces through impact loading.

Inspection and maintenance. Verify the nameplate markings before commissioning and conduct a seat tightness check at the specified test pressure. During service, monitor for stem leakage and replace the packing, typically PTFE or flexible graphite, when required. The needle and seat are the primary wear components; inspect them during scheduled shutdowns and replace them as a matched set to preserve sealing accuracy.

Do you still need to know or purchase the following needle valve products:

Shanghai MeiYan Yi Pump & Valve Co., Ltd.
MeiYan Yi needle valve Contact MeiYan Yi
Kaiweixi Valve Group Co., Ltd.
Kaiweixi needle valve Contact Kaiweixi
Zhejiang Shanliu Valve Technology Co., Ltd.
Shanliu needle valve Contact Shanliu
Shanghai Fengqi Industrial Development Co., Ltd.
FengQi needle valve Contact FengQi